0 item(s)

Fronius Symo Hybrid 3.0-3-S

With power 3.0 kW, the three-phase inverter allows Surplus energy from a photovoltaic system to be temporarily stored in the Fronius Solar Battery. The builtin Multi Flow Technology enables the energy flows to be intelligently managed.


SKU: symo-hib3-0
4027 €2,053.77 VAT included

Availability: Backorder

Delivery time: 15-30* days

Fronius Symo Hybrid 3.0-3-S is available for purchase in increments of 1
Quantity:

With power 3.0 kW, the three-phase inverter allows Surplus energy from a photovoltaic system to be temporarily stored in the Fronius Solar Battery. The builtin Multi Flow Technology enables the energy flows to be intelligently managed.

Technical Data


INPUT DATAFronius Symo Hybrid 3.0-3-S
Max. PV input power 5.0 kW
Max. input current (Idc max) 1 x 16 A
Max. short circuit current, module array 24 A
Min. input voltage (Udc min) 150 V
Feed-in start voltage (Udc start) 200 V
Nominal input voltage (Udc,r) 595 V
Max. input voltage (Udc max) 1,000 V
MPP voltage range (Umpp min – Umpp max) 190 - 800 V
Number of MPP trackers 1
Number of DC connections (PV) 2
BATTERY INPUT 
Maximum output power to battery Depends on connected Fronius Solar Battery.
Maximum input power from battery Depends on connected Fronius Solar Battery.
OUTPUT DATA 
AC nominal output (Pac,r) 3,000 W
Max. output power 3,000 VA
Max. grid power demand 3,000 VA
Max. AC output current (Iac max) 8.3 A
Grid connection (voltage range) 3~NPE 400 V / 230 V or 3~NPE 380 V / 220 V (+20 % / -30 %)
Frequency (frequency range) 50 Hz / 60 Hz (45 - 65 Hz)
Total harmonic distortion < 3 %
Power factor (cos φac,r) 0.85 - 1 ind. / cap.
GENERAL DATA 
Dimensions (height x width x depth) 645 x 431 x 204 mm
Weight 19.9 kg
Degree of protection IP 65
Protection class 1
Overvoltage category (DC / AC) 1) 2 / 3
Inverter design Transformerless
Cooling Regulated air cooling
Mounting Indoors and outdoors
Ambient temperature range -25 - +60°C
Permitted humidity 0 - 100 %
Max. altitude 2,000 m (unrestricted voltage range)
DC PV connection technology 2x DC+ and 2x DC- screw terminals 2.5 - 16 mm²
DC battery connection technology 1x DC+ and 1x DC- screw terminals 2.5 - 16 mm²
AC connection technology 5-pin AC screw terminals 2.5 - 16 mm²
Certificates and compliance with standards VDE AR N 4105, ÖVE / ÖNORM E 8001-4-712, DIN V VDE 0126-1-1
Emergency power function Yes
EFFICIENCY 
Max. efficiency (PV - grid) 97.7 %
Max. efficiency (PV - battery - grid) > 90.0 %
Europ. efficiency (PV - grid) 95.2 %
η at 5 % Pac,r2) 78.5 % / 77.3 % / 66.9 %
η at 10 % Pac,r2) 83.1 % / 83.8 % / 76.6 %
η at 20 % Pac,r2) 90.0 % / 93.0 % / 90.6 %
η at 25 % Pac,r2) 91.2 % / 93.9 % / 91.9 %
η at 30 % Pac,r2) 92.4 % / 94.7 % / 93.3 %
η at 50 % Pac,r2) 94.5 % / 96.7 % / 96.0 %
η at 75 % Pac,r2) 95.1 % / 97.3 % / 96.6 %
η at 100 % Pac,r2) 95.4 % / 97.7 % / 97.0 %
MPP adaptation efficiency > 99.9 %
PROTECTION DEVICES 
DC disconnector Included
Overload behaviour Operating point shift, power limitation
DC insulation measurement Included
Integral RCMU Yes
Reverse polarity protection Yes
INTERFACES 
WLAN / Ethernet LAN Fronius Solar.web, Modbus TCP SunSpec, Fronius Solar API (JSON)
Datalogger and web server Included
Interface to battery and meter Modbus RTU SunSpec (RS485)
1) Testing to IEC 62109-1.
2) And at Umpp min / Udc,r / Umpp max


Subject to modifications
View FileТехнически данни (Aнглийски) / Datasheet    File size: (1.46 MB)
View FileCE Декларация / CE Declaration    File size: (162.77 KB)